To lock out and tag out a forklift for servicing, authorized employees must identify every hazardous energy source, shut down and stabilize the truck, isolate those sources, apply the required locks and tags, control stored energy, and verify isolation before work begins. The exact isolation points and sequence must come from the employer’s written energy-control procedure and the forklift manufacturer’s service instructions.

Removing an unsafe forklift from service is essential, but an out-of-service tag is not automatically a complete lockout/tagout procedure. Forklift LOTO addresses unexpected startup, energization, or the release of stored energy while employees perform servicing or maintenance.

Key Takeaways

  • Forklift shutdown and forklift lockout/tagout are different. Turning off the key does not necessarily isolate electrical, fuel, hydraulic, gravitational, mechanical, or thermal energy.
  • OSHA 29 CFR 1910.178 requires unsafe powered industrial trucks to be removed from service. It also requires the battery to be disconnected before electrical-system repairs.
  • The employer’s energy-control procedure must define the energy sources, isolation points, device application, stored-energy controls, verification method, and return-to-service sequence for the specific truck and task.
  • Electric, LPG, gasoline, and diesel forklifts have different isolation considerations. Do not transfer one procedure to another truck without verification.
  • A status or inspection tag can communicate that a forklift is unavailable. LOTO devices control hazardous energy at the appropriate energy-isolating devices.

When Does a Forklift Need Lockout/Tagout?

Forklift LOTO applies when servicing or maintenance exposes an employee to unexpected startup, energization, or the release of hazardous energy. That determination depends on the work being performed and the hazards the work creates. Routine parking, operator shutdown, or a pre-use inspection does not automatically require full LOTO. Repairing an electrical circuit, entering a danger zone created by the mast or forks, or working where stored hydraulic pressure could release may require energy control.

The OSHA powered industrial truck standard states that any truck not in safe operating condition must be removed from service. Repairs must be made by authorized personnel, and OSHA specifically requires the battery to be disconnected before repairs to the electrical system. These requirements work alongside OSHA’s general lockout/tagout standard, which requires documented energy-control procedures when employees service equipment that could unexpectedly energize or release stored energy.

The practical question is not simply, “Is the key off?” It is, “Can any energy source move, start, fall, pressurize, heat, or otherwise expose the person doing the work?”

Forklift next to a checklist of five hazardous energy sources

Identify the Forklift’s Hazardous Energy Sources

Begin with the truck’s energy-source map and the specific maintenance task. A forklift can contain more than one form of hazardous energy.

Electrical Energy

Electric forklifts can remain connected to a high-capacity battery even when the key is off. Internal-combustion forklifts also use batteries for starting and control circuits. Identify the approved disconnecting point and follow the manufacturer’s sequence. For electrical-system repairs, 29 CFR 1910.178(q)(4) requires battery disconnection before work.

Fuel and Engine Energy

LPG, gasoline, and diesel trucks can retain fuel in lines and components after shutdown. An engine, starter, or connected circuit can also create movement. Follow the manufacturer’s instructions for shutting off the fuel supply, controlling residual fuel or pressure, and isolating associated electrical sources.

Hydraulic and Gravity Energy

Forks, masts, attachments, and elevated loads can fall or move. Lower the forks before servicing whenever the task permits. If work requires an elevated component, use the manufacturer-specified blocking or securing method. Never rely on the hydraulic system alone to hold a raised assembly.

Mechanical and Stored Energy

Moving components, springs, rotating parts, tensioned mechanisms, and residual motion may remain hazardous after the truck stops. Identify where movement must be blocked, restrained, released, or otherwise controlled.

Thermal Energy

Engines, exhaust systems, coolant, batteries, chargers, and other components can remain hot. Cooling time and task-specific PPE may be part of the servicing procedure even after other energy sources are isolated.

How to Lock Out and Tag Out a Forklift

The following checkpoints organize a forklift LOTO procedure. They do not replace the employer’s truck-specific written procedure.

Eight checkpoints for forklift lockout and tagout

1. Prepare for Shutdown

Identify the forklift, the work to be performed, every affected employee, and each energy source that could create exposure. Review the written energy-control procedure and the forklift manufacturer’s service information. Confirm that the selected lockout devices fit the actual isolation points before the truck is taken out of service.

2. Park and Stabilize the Forklift

Move the truck to an authorized servicing location when it is safe to do so. Fully lower the forks or attachment, neutralize the controls, set the parking brake, and secure the truck against movement. If the forklift cannot be moved safely, control the surrounding area and follow the site’s disabled-equipment procedure.

3. Shut Down and Notify

Stop the engine or traction system and remove the operating key as the written procedure directs. Notify affected employees that the truck is being locked out. Removing the key limits normal operation, but it is not a substitute for isolating hazardous energy.

4. Isolate Every Hazardous Energy Source

Operate the energy-isolating devices identified in the procedure. Depending on the truck and task, this may include disconnecting the battery, closing an approved fuel shutoff, isolating another electrical supply, or securing a component that could move. Controls such as push buttons, selector switches, and ignition keys are generally not energy-isolating devices.

5. Apply Personal Locks and Tags

Each authorized employee applies the required personal lock and tag to the designated energy-isolating device or group lockout system. The lock identifies physical control of the energy source. The tag communicates who applied the control and why the equipment must not be operated. Use only devices that match the employer’s procedure and the isolation point.

6. Control Stored or Residual Energy

Relieve, disconnect, restrain, block, or otherwise make stored energy safe. This can include hydraulic pressure, a raised mast, trapped fuel or pneumatic pressure, rotating parts, heat, or electrical charge. If stored energy can accumulate again, the procedure must include continued verification or other controls during the work.

7. Verify Isolation Before Work Begins

Check that no one is exposed, then attempt the procedure’s approved verification method. This may include trying the normal controls, testing for electrical absence with suitable equipment, checking pressure indicators, or confirming that blocked components cannot move. Return controls to neutral or off after the test. Verification must match the hazard. A visual check alone may not be enough.

8. Restore the Forklift to Service Safely

After work is complete, inspect the area, reinstall guards and components, remove tools, and confirm that employees are clear. Authorized employees remove their own devices unless the employer’s documented exception procedure applies. Notify affected employees after removing the devices and before restarting the truck. Restore energy in the approved sequence and complete the required inspection before returning the truck to operation.

Electric Forklift Lockout Considerations

An electric forklift’s battery can power traction, lift, steering, and control circuits. Turning off the key can leave this energy connected. Use the manufacturer-designated battery disconnect or connector, and keep the disconnected components positioned so they cannot accidentally reconnect.

Battery charging introduces separate hazards, including electrical energy, heat, electrolyte, and ventilation requirements. Do not assume a charging procedure is the same as a repair procedure. The applicable written procedure should identify when the charger, battery, or truck must be isolated and how absence of voltage is verified.

For supplies used across a facility’s established energy-control program, a properly selected lockout tagout kit can help organize locks, tags, hasps, and other devices. The kit does not determine compatibility. The employer must match each device to the forklift’s verified isolation point.

LPG Forklift Lockout Considerations

An LPG forklift can retain fuel between the cylinder and the engine after the service valve is closed. The cylinder, connector, hose, regulator, and fuel system also require manufacturer-specific handling. Trained personnel should use the required PPE and follow the truck and cylinder instructions for shutting off the supply and controlling residual fuel or pressure.

Three checks for isolating hazardous energy on an LPG forklift

Closing the service valve addresses the fuel supply. Follow the truck-specific procedure for the remaining energy sources and verify isolation before servicing.

Gasoline and Diesel Forklift Lockout Considerations

Gasoline and diesel forklifts combine fuel, battery, mechanical, hydraulic, gravity, and thermal hazards. Shut down the engine, isolate the battery and fuel sources identified by the procedure, and allow hot components to cool when the task requires it. Control rolling, mast movement, stored hydraulic pressure, and any attachment-specific energy.

Do not loosen fuel lines or open systems to improvise energy release. Use the manufacturer’s service method and appropriate spill, fire, and ventilation controls. A task involving the engine or fuel system can require different controls from work on a wheel, fork, or attachment.

Out-of-Service Tags and LOTO Tags Are Not Interchangeable

OSHA requires an unsafe forklift to be taken out of service. A status tag can warn operators that the truck is unavailable and support the site’s removal-from-service process. However, a warning placed on the steering wheel or key does not isolate a battery, fuel valve, hydraulic system, or raised component.

A lockout tagout tag communicates an energy-control action at the isolating device or approved group lockout point. Under a lockout procedure, it accompanies the physical lock. Under a tagout system, the employer must meet the specific requirements of the OSHA standard. A tag is a warning device, not a physical restraint.

Close-up comparison of a green safety inspection tag and a red danger lockout tag

Common Forklift LOTO Mistakes

  • Treating the ignition key as the only energy control.
  • Applying an out-of-service tag without isolating the sources that can harm the technician.
  • Disconnecting the battery while leaving forks, the mast, or an attachment unsupported.
  • Using the same procedure for electric, LPG, gasoline, and diesel trucks without checking truck-specific instructions.
  • Selecting a lockout device by appearance rather than verified dimensions and fit.
  • Beginning work before stored energy is controlled and isolation is tested.
  • Allowing a second worker to rely on another person’s lock without an approved group lockout process.
  • Restoring power before guards are replaced, tools are removed, and affected employees are clear.

The broader OSHA forklift standard guide can help safety teams connect maintenance controls with operator training, inspections, truck condition, and removal-from-service requirements.

Build the Procedure Around the Truck and the Task

A reliable forklift LOTO process starts with verified equipment information. Record the truck model, power type, relevant attachments, energy-isolating devices, stored-energy hazards, required devices, verification method, and return-to-service checks. Review the procedure whenever the truck, attachment, maintenance task, or energy-control method changes.

The central rule is straightforward: shutdown is not proof of isolation. Authorized employees need a written, truck-specific method for controlling every hazardous energy source before servicing begins.

Frequently Asked Questions

Does turning off a forklift and removing the key count as lockout/tagout?

Not by itself. The key is an operating control, not necessarily an energy-isolating device. The procedure must identify and isolate the battery, fuel supply, hydraulic or gravitational hazards, and any other energy source that could expose the person doing the work.

Does OSHA require the battery to be disconnected before forklift repairs?

OSHA 29 CFR 1910.178(q)(4) requires the battery to be disconnected before repairs to a powered industrial truck’s electrical system. Other servicing tasks may require additional isolation and stored-energy controls under the employer’s energy-control procedure.

How do you lock out an electric forklift?

Follow the employer’s written procedure and the forklift manufacturer’s instructions. Common checkpoints include parking and stabilizing the truck, lowering the forks, shutting it down, disconnecting the battery at the designated point, applying the required lock and tag, controlling stored hydraulic or mechanical energy, and verifying isolation.

How do you lock out an LPG forklift?

Use the truck-specific procedure. It may require closing the cylinder service valve, controlling residual fuel or pressure, isolating electrical energy, lowering and securing the forks or mast, applying approved devices at verified isolation points, and testing the zero-energy condition. Do not assume a generic valve device fits the cylinder.

Is an out-of-service tag the same as a lockout tag?

No. An out-of-service or status tag warns that equipment should not be operated. A lockout/tagout tag identifies an energy-control action at an energy-isolating device or approved group lockout point. The site may use both, but they serve different purposes.


The material provided in this article is for general information purposes only. It is not intended to replace professional/legal advice or substitute government regulations, industry standards, or other requirements specific to any business/activity. While we made sure to provide accurate and reliable information, we make no representation that the details or sources are up-to-date, complete or remain available. Readers should consult with an industrial safety expert, qualified professional, or attorney for any specific concerns and questions.